Term Image

Microplate Spectrophotometer (or Microplate Readers):

LTEK CO. LTD in South Korea develops and manufactures advanced microplate readers for the biomedical and global life science sectors. The INNO microplate reader range ensures consistent successful outcomes. This line includes absorbance, luminescence, and fluorescence microplate spectrophotometers.

Showing all 10 results

LTEK INNO Microplate Reader Absorbance

£ 5,598.96 ex. VAT

The LTEK INNO microplate spectrophotometer is the 21st century new generation instrument for all the researches that deals with the absorbance and luminescence. INNO is able to read microplate with 6 ~ 384 wells and can perform endpoint, kinetics reading, and spectral scanning.
• Monochromator based UV-Vis Absorbance
• 200nm to 999nm wavelength range
• Wavelength selection Monochormator
• Xenon flash lamp and Absorbance detection for flexibility and performance
• Two step speed Shaking mode
• 2uL low volume nucleic acid quantification with NANO-VC Plate (Option)
• Provides INNO-X Ex software with powerful diverse functions

LTEK INNO-H Multi-mode Microplate Reader

£ 35,156.25 ex. VAT

LTEK High Multi-mode microplate reader
Monochromator Absorbance, Monochromator Fluorescence, Fiber Luminescence, Filter Fluorescence,Dichroic Fluorescence & Polarization (equipable option), Shaking & TRF

INNO-H has two main detecting functions. INNO-H has Fluorescence measurement with Monochromator excitation and
emission module, and Fluorescence measurement with the Dichroic Fluorescence measurement module.
In Fluorescence measurement, the monochromator captures EX / EM wavelengths without filters. It is straightforward to measure, and even if the wavelength to be measured is different, there is no need to purchase filters separately. Users do not need to buy a filter; they change the wavelength in the UI. Dichroic Fluorescence measurement module offers unique features. The most sensitive Fluorescence measurement technology, and ideal for measuring low-concentration samples.

LTEK INNO-HD Multi-mode Microplate Reader

£ 20,833.34 ex. VAT

LTEK High Multi-mode Microplate Reader Filter Fluorescence, Filter Luminescence, Fluorescence Polarization (equipable option), Shaking, Incubation & TRF

INNO-H has two main detecting functions. INNO-H has Fluorescence measurement with Monochromator excitation and
emission module, and Fluorescence measurement with the Dichroic Fluorescence measurement module.
In Fluorescence measurement, the monochromator captures EX / EM wavelengths without filters. It is straightforward to measure, and even if the wavelength to be measured is different, there is no need to purchase filters separately. Users do not need to buy a filter; they change the wavelength in the UI. Dichroic Fluorescence measurement module offers unique features. The most sensitive Fluorescence measurement technology, and ideal for measuring low-concentration samples.

LTEK INNO-HM Multi-mode Microplate Reader

£ 2,604.16 ex. VAT

LTEK High Multi-mode Microplate Reader Monochromator Absorbance, Monochromator Fluorescence, Shaking, Incubation, TRF

INNO-H has two main detecting functions. INNO-H has Fluorescence measurement with Monochromator excitation and
emission module, and Fluorescence measurement with the Dichroic Fluorescence measurement module.
In Fluorescence measurement, the monochromator captures EX / EM wavelengths without filters. It is straightforward to measure, and even if the wavelength to be measured is different, there is no need to purchase filters separately. Users do not need to buy a filter; they change the wavelength in the UI. Dichroic Fluorescence measurement module offers unique features. The most sensitive Fluorescence measurement technology, and ideal for measuring low-concentration samples.

LTEK INNO-HML Multi-mode Microplate Reader

£ 28,645.84 ex. VAT

LTEK High Multi-mode microplate reader Monochromator Absorbance, Monochromator Fluorescence,Fiber Luminescence, Shaking, Incubation, TRF

INNO-H has two main detecting functions. INNO-H has Fluorescence measurement with Monochromator excitation and
emission module, and Fluorescence measurement with the Dichroic Fluorescence measurement module.
In Fluorescence measurement, the monochromator captures EX / EM wavelengths without filters. It is straightforward to measure, and even if the wavelength to be measured is different, there is no need to purchase filters separately. Users do not need to buy a filter; they change the wavelength in the UI. Dichroic Fluorescence measurement module offers unique features. The most sensitive Fluorescence measurement technology, and ideal for measuring low-concentration samples.

LTEK INNO-M Microplate Reader Absorbance & Luminescence

£ 9,765.63 ex. VAT

LTEK Microplate INNO-M Spectrophotometer Absorbance & Luminescence is based with monochromatic measuring technology which allows your research to higher level.

• 200nm to 999nm wavelength range
• Wavelength selection monochromator
• Xenon flash lamp lamp for a semi-permanent life time
• Multi-mode (Absorbance + Luminescence)

INNO-M has powerful functions with high accuracy of result data. It is able to report result graphics in excel file format.
INNO-M software supports Linear, Quadratic regression, Cubic regression, Log regression, Exponential regression, Linear logarithmic regression, point-to-point, and 4PL regression graphic options.

LTEK INNO-S Microplate Reader Absorbance, Luminescence, Fluorescence, Shaking, Incubation & TRF

£ 17,578.13 ex. VAT

LTEK Microplate reader Absorbance, Luminescence, Fluorescence, Shaking, Incubation & TRF.

INNO-S has three main detecting functions. Since INNO-S is a monochromator-based microplate spectrophotometer for the absorbance measurements, it requires zero filters and allows you to measure from 200 to 999 nm freely at your choice of 1nm increment. Also Xenon lamps in absorbance will serve the instrument semi-permanent life time which brings the comfortable experiences to the users since the lamps do not need to be replaced such as halogen lamps.
Fluorescence using High Power LED to provide TRF (Time Resolved Fluorescence) and various convenient features as ready to run at “on”. Also HPL has semi-permanent life time which the user does not have to go through the burdens such as switching the fluorescence light source every once in a while.

LTEK INNO-SA Microplate Reader Absorbance, Shaking & Incubation

£ 13,020.84 ex. VAT

LTEK Microplate reader
Absorbance, Shaking & Incubation

LTEK INNO-SF Microplate reader Fluorescence, Luminescence, Shaking, Incubation & TRF

£ 14,322.91 ex. VAT

LTEK Microplate reader
Fluorescence, Luminescence, Shaking, Incubation & TRF

LTEK INNO-W96 Microplate Washer 96 pins

£ 6,510.41 ex. VAT

LTEK Microplate washer 96 pins, singlerow controllable
Description
• Microcomputer control, automatically complete the plate washing operation.
• The liquid level sensing function automatically detects the liquid level, and automatically alarms when the cleaning liquid is insufficient and the waste liquid is overflowing.
• The user-friendly operating system allows users to customize the plate type, set the number of washes, the amount of wash solution, the way to wash the plate, the suction point, the soaking and shaking time and other parameters.
• The wash head is self-balancing, has two-point aspiration, and performs bottom flushing.
• 2 kinds of Automatic washing, Soaking and Shaking, to reduce the interference adsorption during the reaction; time adjustable.