Take melting point measurements of up to three samples at once for greater efficiency. Easy-to-follow instructions are printed directly on the unit. Place your sample in a capillary tube and insert it into the aluminum block. Manually set the heating rate between 1°C and 20°C per minute, up to a maximum of 250°C. Lowering the heating rate as you near the expected melting point temperature will increase the accuracy of the reading. Observe the sample through the magnifying lens until the melt occurs and read the melt temperature from the thermometer. The apparatus is supplied with open-ended capillary tubes. One end should be sealed with a Bunsen burner, or purchase optional capillary tubes separately that are already sealed. Order the optional brass cooling plug to speed up cooling when multiple runs are needed.
Cole-Parmer MP-100 Stuart Analog Melting Point Apparatus; 230 VAC
£ 713.77 ex. VAT
Model Number MP-100, Melting point method Digital, No of samples 3, Temperature range 50 to 250ºC, Temperature resolution 0.1ºC, Display 40x 4 LCD, Ramp rate 0.5-10ºC in 0.1ºC increments, Temperature sensor PT100 Platinum resistance, Memory 8 results per tube, Accessory printer Yes, Date/time display Yes, Cooldown time 250-50ºC 12 mins, Heat up time 50-250ºC 1ºC to max of 20ºC per minute, Electrical supply 230V, 50Hz, 50W, Onboard capillary storage Yes, In-built glass cutter Yes, Language variants English, German, French, Italian, Spanish, Temperature units ºC, Dimensions h x d x w 110 x 140 x 370, Net weight (kg) 1.7.
Available on backorder
Parameter | Value |
---|---|
Brand | |
Country of origin | China |
Warranty | & |
Product type | Analog Melting Point Apparatus |
Power VAC | & |
Power Hz | 50/60 |
Shipping weight kg | 4 |
Estimated Dims L cm | 61 |
Estimated Dims W cm | 27 |
Estimated Dims H cm | 35 |
Filter type | Melting Point |
Min working temperature | 50°C |
Max working temperature | 250°C |
pa_type | 1215 |
Heater Power watts | 50 |
Display | No |
Temperature Sensor | Glass Thermometer |
Types of Control | Analogue |
Positions | 3 samples |
Memory | No |
Accesssory printer | & |
Heat up time | 1° to 20°C per minute (variable) |
Optional Accessories
Product | |
---|---|
Capillary tubes measure 100 mm L, 1.9 mm OD, 1.3 mm ID, and 0.3 mm wall thickness.
SKU: 03013-65 |
|
Cole-Parmer Brass Cooling Plug for Analog Melting Point Apparatus
SKU: 03013-66 |
|
Cole-Parmer Glass Capillary Tubes, Open Both Ends; 100/PK
SKU: 03013-63 |
|
Cole-Parmer Glass Capillary Tubes, Open One End; 100/PK
SKU: 03013-64 |
|
Cole-Parmer Melting Point Calibration Kit
SKU: 99967-49 |
|
Cole-Parmer Spirit-Filled Thermometer, 0 to 250°C
SKU: 03013-62 |
SKU: 03013-65