Complete with 5 simultaneous detectors Na, K, Li, Ca, Ba, Gas Regulator, Air Compressor, Inbuilt Starter Pack and Fluids Kit “Just Add Gas”, (100V-250V, 50/60Hz), Drain trap connecting tubes, operating manual PC software (with Interface cable), Including Starter Pack Containing Fluid Kit Diluent Concentrate (500ml), Decon 90 (150ml), Sodium Standard 10,000ppm (150ml), Potassium Standard 10,000ppm (150ml), Lithium Standard 10,000ppm (150ml), Calcium Standard 10,000ppm (150ml), Barium Standard 10,000ppm (150ml), Labware Kit 1ml Pipettes(10), 10ml Pipettes (10), 100ml Volumetric Flask (1) and Sample Cups (100)
Sample rate
2 – 3.5ml/min
Tubing materials
Silicone and Tygon®
Required desk space for Instrument
50cm (H) x 45cm (W) x 45cm (D)*
For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.
Instrument size
XP Flame Photometer
51cm (H) x 39cm (W) x 35cm (D)
(20in x 15in x 14in)
Shipping
65cm (H) x 49cm (W) x 43cm (D)
(25in x 19in x 17in)
Weight
XP Flame Photometer – 14kg (30.8lbs)
Shipping – 25kg (55.1 lbs)
Power requirements
100V – 250V AC at 50 or 60Hz automatically selecting
Readout
LCD, four line, alpha numeric, back lit.
Optimal range
Single point calibration
Na 0.1 – 60ppm
K 0.05 – 100ppm
Li 0.05 – 50ppm
Ca 1.0 – 100ppm
Ba 1.6 – 100ppm
Multi Point Calibration
Na 0.1 – 1000ppm
K 0.05 – 1000ppm
Li 0.05 – 1000ppm
Ca 1.0 – 1000ppm
Ba 5.0 – 3000ppm
Reproducibility
<1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation).
Specificity
Na/K/Li = <1% to each other when equal in concentration at <100ppm
Limit of detection (LOD) and
limit of quantification (LOQ)
LOD LOQ
Na – 0.03ppm Na – 0.1ppm
K – 0.02ppm K – 0.05ppm
Li – 0.02ppm Li – 0.05ppm
Ca – 0.3ppm Ca – 1ppm
Ba – 1.6ppm Ba – 5.0ppm
Time to stability
Less than 15 seconds after sample is introduced into the flame.
Ions measured
Simultaneous measurement of Na, K, Li, Ca, Ba
Interfaces
USB
0-2.5 volt output (based on sample concentration linked to element of users choice)
Optional 4-20mA output in place of the above
Optional integrated printer
.csv and .pdf generated reports and files via FP-PC software
Recommended minimum warm up time based on ambient temperature
21ºC – 25 minutes
Fuel requirement
Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min
*with modifications. BWB Technologies recommends either Propane or Butane for optimum results.